Timer Relay 10A - 0-999 min - 6-30V - Cycle Switch M792 Arduino
Specification:
- Power supply: 6V - 30V or micro USB 5.0V
- Trigger: 3.8V - 24V
- Time range: 0-999 minutes
- Working in the temperature range: -40-85C
- Dimensions: 62mm * 38mm * 19mm
- Relay 10A 230V-AC 30V-DC
USER MANUAL:
STOP button turn the relay on / off (The countdown is working - the relay is off)
SET button held for a long time - selecting one of the functions and moving to the attributes of the function
SET button held briefly - display of function attributes
Module programming procedure:
Press the stop button selecting ON.
Wait until 000 appears on the display
Long press SET -> Select program with UP / DOWN buttons
Briefly press SET -> Flashing OP on the display -> 000. -> Enter the duration of the attribute with the UP / DOWN buttons
Select the time unit with the STOP button:
000 .-> Second
00.0 -> The tenth of a second (05.5 = 5.5 seconds)
0.0.0. -> Minute (0.0.1. = 1 minute)
Long press SET -> After the flashing of the program number, eg P1.1, the procedure will be finished
Description of programs (functions):
P1.1 - After the Trigger signal is given, the relay is switched on and the time set as an attribute of the OP function is counted down, then the relay turns off (giving the Trigger signal during the countdown does not count down from 0)
P1.2 After the Trigger signal is given, the relay is turned on and the time set as an attribute of the OP function is counted down, then the relay turns off (giving the Trigger signal during the countdown causes the countdown from 0)
P1.3 After the Trigger signal is given, the relay is turned on and the time set as an attribute of the OP function is counted down, then the relay turns off (giving the Trigger signal during the countdown turns off the relay and resets the countdown)
P-2 After the Trigger signal is given, the countdown of the time set as an attribute of the CL function follows, then the relay is switched on and the time set as an attribute of the OP function is counted down, then the relay turns off (giving the Trigger signal during the countdown does not count down from 0)
P3.1 After the Trigger signal is given, the relay is turned on and the time set as an attribute of the OP function is counted down, then the relay is turned off and the time set as an attribute of the CL function is turned off, the process (CYKL) is repeated a certain number of times entered in the LOP attribute (--- in the attribute LOP means an infinite loop) giving the Trigger signal during the countdown turns off the relay and resets the countdown
P3.2 After connecting the module to the power supply, the relay is automatically turned on and the time set as an attribute of the OP function is counted down, then the relay is turned off and the time set as an attribute of the CL function is counted down, the process (CYKL) is repeated a certain number of times entered in the LOP attribute (--- in the LOP attribute it means an infinite loop)
P - 4 After the Trigger signal is given, the relay is turned on, the countdown of the time set as an attribute of the OP function starts from the Trigger "disappearance" (the relay is turned on until the countdown ends) Giving the Trigger signal during the countdown resets the counter and waits for the "disappearance" Trigger (the relay is always on)
Depending on the delivery, the module has a Display Sleep option or not
Display Sleep Mode - If Trigger is not given for 5 minutes, the display will turn off
Turn on the Display Sleep Mode: Press and hold the STOP button for about 3 seconds - C - P will appear on the display
Disable the Display Sleep Mode: Press the STOP button for about 3 seconds - the display will show 0 - d