DC 5-60V Real Time Delay Relay Module - 10A - RTC - XY-BJ
Delayed ON module controlled by the real time clock RTC
The delayed activation module, which is controlled by the real-time clock, allows the devices to be switched on by means of a relay. The device allows you to set the relay output on / off time on a specific day and month. The system also allows you to set 5 time periods. Each time period can be set according to 5 different programs available in the module. Thanks to the built-in real-time clock, switching takes place in real time. The module is powered by a micro USB connector or ARK terminal block connector. The voltage that we can lead to the second connector has a very wide range and ranges from 5V to 60V.
Delayed relay activation module controlled by real time clock RTC BTE-679 time programmer XY-BJ
Technical Data:
microprocessor-controlled relay - timer
Model: XY-BJ
5 time periods can be set
5 different operating programs can be selected for each set time
supply voltage: 5.0V to 60V terminal block connector or 5V microUSB socket
maximum load of the relay contacts: 10A / 250VAC or 10A / 30VDC
built-in CR1220 battery (included) socket for module memory (clock)
built-in alarm buzzer
LED indicator of switching on the relay
automatic backlight off after 10 minutes of inactivity
LED display informing about the current time and set parameters
Terminal block sockets for screwing on the wires
Programs:
P-1: Time can be set. The relay works every day at the given time. Relay off to OPE time point. Relay energized to CLE time point. After the CLE time, the relay is turned off again.
P-2: Time can be set. Relay off to OPE time point. Relay energized to CLE time point. After the CLE time, the relay is turned off again.
P-3: Option to set the time and date (month and day) when the relay is to operate. Relay off to OPE time point. Relay energized to CLE time point. After the CLE time, the relay is turned off again.
P-4: Option to set the date (month and day) and time of switching on and the date (month and day) and time of switching off the relay. Relay off to OPE time point. Relay energized to CLE time point. After the CLE time, the relay is turned off again.
P-5: Possibility to set the date (day) and time of switching on and the date (day) and time of switching off the relay. Relay off to OPE time point. Relay energized to CLE time point. After the CLE time, the relay is turned off again.