Save to shopping list
Create a new shopping list

W1209 Digital Thermostat 12V with Temperature Sensor -50°C/+110°C + Acrylic Housing

W1209 Digital Thermostat 12V with Temperature Sensor -50°C/+110°C + Acrylic Housing
W1209 Digital Thermostat 12V with Temperature Sensor -50°C/+110°C + Acrylic Housing
W1209 Digital Thermostat 12V with Temperature Sensor -50°C/+110°C + Acrylic Housing
W1209 Digital Thermostat 12V with Temperature Sensor -50°C/+110°C + Acrylic Housing
W1209 Digital Thermostat 12V with Temperature Sensor -50°C/+110°C + Acrylic Housing
W1209 Digital Thermostat 12V with Temperature Sensor -50°C/+110°C + Acrylic Housing
W1209 Digital Thermostat 12V with Temperature Sensor -50°C/+110°C + Acrylic Housing
W1209 Digital Thermostat 12V with Temperature Sensor -50°C/+110°C + Acrylic Housing
9,08 €
/ pc
Easy return of this product within 14 days from the date of purchase for any reason
Free delivery for orders over 150,00 €
- NEXT DAY delivery throughout Europe with

Thermostat module with display that allows you to control the device up to 2.3 kW based on temperature. Powered with 12 V. Operating range from -50 ° C to 110 ° C. The set also includes a waterproof temperature probe with a cable.

Specification:

supply voltage - 12V
temperature regulation range from -50 * C to 110 * C
indication resolution - 0.1 * C (-9.9 to 99.9 * C) 1 * C (remaining range)
output load 20A / 14VDC 20A / 125VAC
NTC 10K measuring probe in a waterproof tube
dimensions - 41x49x18mm
Housing

Programming:

To enter programming mode, hold the SET button for about 5 seconds

selecting the programming mode: P0 - P6 is selected with the + and - buttons

enter the selected mode by pressing the SET button

confirmation of the selected value with the SET button


Programming Modes:
P0 - cooling or heating selection

P1 - hysteresis setting from 0.5 ° C to 15 ° C

P2 - upper temperature limit, range from -45 ° C to 110 ° C

P3 - lower temperature limit, range from -50 ° C to 110 ° C

P4 - thermometer calibration in the range -7 * C to 7 * C (use when temperature indications are incorrect)

P5 - relay activation delay time in the range of 0min to 10s

P6 - too high temperature alarm, adjustable from 0 to 110 * C

simultaneous pressing of the + and - buttons at the moment of switching on the supply voltage causes a reset to the factory settings.